The paper presents a theoretical and experimental analysis of the cooling system of a 150 MW coal-fed power plantlocated in central Italy, where ten evaporative towers cool down the plant using water taken from a river. An updatedresearch on the state-of-the-art evaporative tower cooling system has been carried out to show the theoretical analysisof the tower heat and mass balance, and taking into account sensible and latent heat exchanged during the processeswhich occur inside these towers. A long-term statistical data analysis has been carried out concerning the operation ofthe cooling towers; this information was correlated to the corresponding values of the environmental conditions of thesite, and used to evaluate heat exchanged by the towers in the various conditions. The whole analysis permitted toevaluate the optimal conditions as far as the operation of the towers is concerned and to suggest an improvement ofthe plant. Finally, since plant re-powering has become quite a common issue today, the evaluation of the coolingsystem operation was conducted under the hypothesis of an increase in the plant nominal power of about 10%.

Theoretical and experimental analysys of the evaporative towers cooling system of a coal-fired power plant

Asdrubali Francesco;
2006-01-01

Abstract

The paper presents a theoretical and experimental analysis of the cooling system of a 150 MW coal-fed power plantlocated in central Italy, where ten evaporative towers cool down the plant using water taken from a river. An updatedresearch on the state-of-the-art evaporative tower cooling system has been carried out to show the theoretical analysisof the tower heat and mass balance, and taking into account sensible and latent heat exchanged during the processeswhich occur inside these towers. A long-term statistical data analysis has been carried out concerning the operation ofthe cooling towers; this information was correlated to the corresponding values of the environmental conditions of thesite, and used to evaluate heat exchanged by the towers in the various conditions. The whole analysis permitted toevaluate the optimal conditions as far as the operation of the towers is concerned and to suggest an improvement ofthe plant. Finally, since plant re-powering has become quite a common issue today, the evaluation of the coolingsystem operation was conducted under the hypothesis of an increase in the plant nominal power of about 10%.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12071/39850
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact